XQP275

360 View Video

Product Description

This is EU Stage IIIA emission standard capable generator set. A unique XQP feature is the clutch fan drive technology, where the fan no longer needs to runs continuously at full speed and power. This saves additional fuel, and lowers noise output; an ideal feature when operating at lower loads, in cooler temperatures, or most importantly, in evenings when noise levels are most noticeable. Each model delivers increased flexibility by easily switching between 50 and 60 Hz, which allows one machine to satisfy varying load requirements across diverse regions and applications including mining, manufacturing, oil and gas and construction.

Specifications
Us
Metric
Generator Set
Rating Prime
275 kVA
Frequency
50/60 Hz
Voltage
127 - 480 V
Engine
Engine
Cat C9 ACERT Diesel Engine
Fuel
Diesel
Dimensions
Width
55 in
1400 mm
Height
84 in
2124 mm
Length
160 in
4065 mm
Weight - With Lube Oil and Coolant
8553 lb
3880 kg
Fuel Consumption EU Stage IIIA
100% Load 50Hz
15.8 gal/hr
59.7 l/hr
100% Load 60Hz
20 gal/hr
75.7 l/hr
75% Load 50Hz
12.7 gal/hr
48.1 l/hr
75% Load 60Hz
15.8 gal/hr
59.9 l/hr
50% Load 50Hz
9.4 gal/hr
35.5 l/hr
50% Load 60Hz
11.6 gal/hr
43.8 l/hr
Standard/Optional

Standard Equipment

CAT C9 Diesel Engine
Generator
Air Filter
Cat Connect remote monitoring
Cooling System
Charging / Starting System
Fuel System
Control Panel
Distribution
Structure
Enclosure
Exhaust
Lube Oil
General

Your time is valuable, and your business, much appreciated. Thanks for visiting our website. You can count on us for realistic answers to your equipment needs, state-of-the-art technology, experienced application specialists, flexible acquisition options and customized financing. We look forward to answering your questions.